Search results for "Silicon compound"
showing 10 items of 24 documents
Magnetic molecularly imprinted polymers for the selective determination of cocaine by ion mobility spectrometry
2018
Abstract Magnetic molecularly imprinted polymers (MMIPs) were prepared for cocaine recognition by bulk polymerization in the presence of magnetic nanoparticles (MNPs). Two reagents (polyethylene glycol (PEG) and 3-(trimethoxysilyl)propyl methacrylate (V)) were used for MNPs modification. MMIPs were characterized and compared in terms of loading capacity, reusability, accuracy and precision for the extraction of cocaine from saliva samples. It was observed that V-MMIPs gave higher physical stability than PEG-MMIPs. Thus, V-MMIP were used for the analysis of cocaine users saliva. The developed procedure based on ion mobility spectrometry (IMS) provided limits of detection and quantification o…
Electronic excitations of 1,4-disilyl-substituted 1,4-disilabicycloalkanes: a MS-CASPT2 study of the influence of cage size.
2007
We present a multistate complete active space second-order perturbation theory computational study aimed to predict the low-lying electronic excitations of four compounds that can be viewed as two disilane units connected through alkane bridges in a bicyclic cage. The analysis has focused on 1,4-disilyl-1,4-disilabicyclo[2.2.1]heptane (1a), 1,4-bis(trimethylsilyl)-1,4-disilabicyclo[2.2.1]heptane (1b), 1,4-disilyl-1,4-disilabicyclo[2.1.1]hexane (2a), and 1,4-bis(trimethylsilyl)-1,4-disilabicyclo[2.1.1]hexane (2b). The aim has been to find out the nature of the lowest excitations with significant oscillator strengths and to investigate how the cage size affects the excitation energies and the…
Assessment for the mean value total dressing method: Comparison with coupled cluster including triples methods for BF, NO+, CN+, C2, BeO, NH3, CH2, H…
1997
Limited previous experience with the mean value total dressing (MVTD) method had shown that MVTD energies for closed shell systems are generally better than CCSD(T) ones compared to FCI. The method, previously published as total dressing 2′(td-2′), is based on the single reference intermediate Hamiltonian theory. It is not a CC method but deals in a great part with the same physical effects that CC methods that incorporate amplitudes of triples such as CCSDT or its CCSDT-1n approaches. A number of test calculations comparing to diverse CC methods, as well as FCI and experiment when available, have been performed. The tests concern equilibrium energies in NH3 and CH2, equilibrium energies an…
Ordered networks of rat hippocampal neurons attached to silicon oxide surfaces.
2001
The control of neuronal cell position and outgrowth is of fundamental interest in the development of applications ranging from cellular biosensors to tissue engineering. We have produced rectangular networks of functional rat hippocampal neurons on silicon oxide surfaces. Attachment and network formation of neurons was guided by a geometrical grid pattern of the adhesion peptide PA22-2 which matches in sequence a part of the A-chain of laminin. PA22-2 was applied by contact printing onto the functionalised silicon oxide surface and was immobilised by hetero-bifunctional cross-linking with sulfo-GMBS. Geometric pattern matching was achieved by microcontact printing using a polydimethylsiloxa…
Simultaneous analysis of lysine, Nɛ-carboxymethyllysine and lysinoalanine from proteins
2007
Protein quality was assayed by simultaneous measurement of lysine (Lys), carboxymethyllysine (CML) and lysinoalanine (LAL). GC-FID analysis of N-tert-butyl dimethylsilyl (tBDMSi) derivatives of these amino acids was undertaken. tBDMSi derivates were separated on a CP-SIL 5CB commercially fused silica capillary column (25 m × 0.25 mm i.d., 0.25 μm film thickness) employing a thermal gradient programmed from 200 to 300 °C. The identity of tBDMSi derivatives of Lys, CML and LAL was established by GC–MS while FID detection was employed for quantification. Analytical parameters such as linearity (lysine 350–4200 μM, LAL 3–81 μM, CML 16–172 μM), precision (1–13% variation coefficients), accuracy …
18F-labeling of peptides by means of an organosilicon-based fluoride acceptor.
2006
Fluorine-18 is among the most commonly used radionuclides for positron emission tomography (PET). This non-invasive imaging technique is capable of providing in vivo information about the distribution of radiolabeled biomolecules by 1808 coincidence detection of two simultaneously emitted photons from positron–electron annihilation. Although a number of different radiotracers have been successfully employed in PET, only a few, such as 2-[F]fluoro-2-deoxy-d-glucose (FDG) and [F]fluorodopa, have gained widespread application in nuclear medicine. The reason for this is that the regioselective introduction of F into tracer molecules is often non-specific and radiochemical yields (RCY) of the Fl…
Redox tuning and species distribution in Maya Blue-type materials: a reassessment.
2013
Maya Blue-type specimens prepared from indigo (1 wt %) plus kaolinite, montmorillonite, palygorskite, sepiolite, and silicalite are studied. Liquid chromatography with diode array detection, ultra-performance liquid chromatography coupled with mass spectrometry, and pyrolysis-silylation gas chromatography-mass spectrometry analyses of the extracts from these specimens combined with spectral and solid-state voltammetry, electrochemical impedance spectroscopy, and scanning electrochemical microscopy techniques provide evidence for the presence of a significant amount of dehydroindigo and isatin accompanying indigo and other minority organic compounds in all samples. Solid-state electrochemist…
Biological oxygen apparent transmissibility of hydrogel contact lenses with and without organosilicon moieties.
2003
The instrument oxygen transmissibility (IOT) of organosilicon hydrogels, measured by electrochemical procedures, is 5-10 times larger than that of conventional hydrogels. A method is described that allows the estimation of the oxygen tension at the lens-cornea interface for closed- and open-eyelids situations by combining the IOT of the hydrogels and corneal parameters such as corneal thickness, corneal permeability and oxygen flux across the cornea. From these results the biological oxygen apparent transmissibility (BOAT) is obtained, an important parameter which an multiplication with the pressure of oxygen on the external part of the lens gives the oxygen flux onto the cornea. Contact le…
Responsivity measurements of silicon carbide Schottky photodiodes in the UV range
2014
We report on the design and the electro-optical characterization of new classes of 4H-SiC Schottky UV detectors, fabricated employing Ni 2 Si interdigitated strips. We have measured, in dark conditions, the forward and reverse I-V characteristics as a function of temperature and C-V characteristics. Responsivity measurements of the devices, as function of wavelength in the UV range, of package temperature and of applied reverse bias are reported. We also compared devices featuring different strip pitch sizes, discussing their performances, and found the device exhibiting best results.
Experimental and Theoretical Studies on Magnetic Exchange in Silole-Bridged Diradicals.
2006
International audience; Five bis(tert-butylnitroxide) diradicals connected by a silole [2,5-R2-3,4-diphenylsilole; R = Me3CN(®O.bul.)Z; Z = p-C6H4 (7a), p-C6H4C6H4-p (7b), 1,4-naphthalenediyl (7c), m-C6H4 (7d)] or a thiophene [2,5-R2-thiophene; R = p-Me3CN(®O.bul.)C6H4 (12)] ring as a coupler were studied. Compd. 12 crystallizes in the orthorhombic space group Pna21 with a 20.752(5), b 5.826(5), and c 34.309(5) .ANG.. X-ray crystal structure detn., electronic spectroscopy, variable-temp. EPR spectroscopy, SQUID measurements and DFT computations (UB3LYP/6-31+G*) were used to study the mol. conformations and electronic spin coupling in this series of mols. Whereas compds. 7b, 7c, and 7d are q…